Can answer questions in the residental,commericial electrical fields. From Trouble shooting to new installation,service changes and related items. We can answer questions about Generators,We are a Authorized dealer and service center for a few major Brands Visit us on line at www.gbelect.net
30 years in the electrical trade. Ran jobs from small houses to large shopping centers to new construction on Wal-Marts Nursing homes and Factories, CCTV,CARD ACCESS SYSTEMS
NFPA,NEC CODE ENFORCEMENT ORGANIZATION,VNM/MC VIET NAM VET OF OHIO VIET NAM VET K-9 HANDLER ASSOCIATION VETERANS OF FOREIGN WARS
OSHA APPROVED TRAINING,UPTO DATE CODE BOOK DISCUSSIONS,MEMBER NFPA FROM 1996 TO PRESENT MEMEBR OF ELECTRICAL CONTRACTORS NETWORK OHIO CONTRACTORS LICENSE FLA CONTRACTORS LICENSE MASTER ELECTRICIAN IN 5 STATES
HONORABLE DISCHARGE FROM THE UNITED STATES NAVY VIET NAM SERVICE MEDAL,GOOD CONDUCT AWARD EXPERT MARKMANS SHIP AWARD
WAL MART, TOYS R US,BLIMPIES REST,McDONALDS CORP,ADENA HEALTH SYSTEMS, OSHP, STATE OF OHIO, US COAST GUARD,
We are always learning something new everyday. As long as I have been in this field I learn everyday something about the trade.
This is a very shocking subject!!
Every time you think you know the National Electrical Code they Change it !!
| User | Date | K | C | T | P | Comments |
|---|---|---|---|---|---|---|
| John | 11/02/09 | 10 | 10 | 10 | 10 | Thank you sir very much! |
| Reid | 10/30/09 | 10 | 10 | 10 | 10 | Ben, I completely forgott about this. I ..... |
| JR. | 10/27/09 | 10 | 10 | 10 | 10 | |
| jim | 09/24/09 | 10 | 10 | 10 | 10 | Thanks so much, I'll check it tonite ..... |
| Mike | 09/18/09 | 10 | 10 | 10 | 10 | Thank you for the fast response. I ..... |
Lee what you can do is add a sub-panel you need to make sure the sub panel has the 2 hots a neutral and a ground. Keep the ground and neutral separate by not using the bonding screw. You will have to
Jason Those switches are used to turn on half of a outlet usually the top.Shut the switches off and then test every outlet upper one and lower one.You should be able to find 1/2 that's dead then by operating
John What this sounds like is the neutral or ground may be bad or nicked. Check the voltage between the hot wires and the ground you should get 120 volts.Voltage drop may not be a issue as this building
Chris Have you changed the switch? Switches can go bad,what you can do is remove the switch and take the 2 wires off the switch and connect them together with a wire nut and then turn the circuit back
JR That depends one the amperage draw on the unit.There is a name plate on the welder it tells you the voltage,amps and cycles there you would find the information on the breaker. 30 amp you need a #10